204
/ Planning the installation
Modular ICS 7.1 Installer Guide
N0130943 02
Internal wiring requirements
The following section describes the cable required for the
Norstar loop and an ISDN S reference point S loop.
Norstar loop
å
one, two or three twisted pair cables per telephone
å
dc loop resistance of less than 64
Ω
å
cable length (0.5 mm or 24 AWG) less than
300 m (1000 ft.)
å
use of a station auxiliary power supply (SAPS) for loops
300 m (1000 ft.) to 790 m (2600 ft.). The SAPS must be a
Class 2 power source that is UL listed and CSA certified.
å
no bridge taps
ISDN S reference point (S Loop)
å
no longer than 1000 m (3,200 ft.) for point to point
å
no longer than 450 m (1,475 ft.) on a point-to-multipoint
extended passive bus
Tips -
The following combinations are not supported with
the MICS 7.1 and MICS-XC 7.1 systems:
•
two 2-port expansion cartridge system (four fiber ports
total)
•
a six-port and a two-port expansion combination
(eight fiber ports total)
In a fully expanded system using 72 digital channels, consider
installing two service cartridges to prevent blocking of
incoming calls due to lack of DTMF resources, as there are
only four DTMF tone receivers per cartridge.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...