242
/ Inserting a cartridge
Modular ICS 7.1 Installer Guide
N0130943 02
Receive and transmit jumper loop connections
Connecting expansion modules
If your system includes fiber Trunk Modules, fiber Station
Modules, Data Modules or Analog Station Modules, you need
to connect the modules to the Expansion Cartridge by means
of fiber cables.
Order of connection
In order to keep the default port and telephone numbering:
•
Connect Trunk Modules to the Expansion Cartridge
beginning at the top and working down.
•
Connect Station Modules to the Expansion Cartridge
beginning at the bottom and working up.
Analog Station Module
If you are installing the ICS system with an ASM, refer to the
diagram below.
Connect jack 1 on the ASM to the first available fibre cable
link on the CCU.
Loop
RX and TX shorting straps
1
J3 and J4
2
J7 and J8
3
J1 and J2
4
J5 and J6