System prgrming /
477
N0130943 02
Modular ICS 7.1 Installer Guide
12. Press
CHANGE
to enter a different number.
13. Press
‘
. The display shows
Max outgoing:23
.
14. Press
CHANGE
to enter a different number.
Release Reasons
Installer password required
This feature is useful for diagnostic purposes. It shows the
reason why an ISDN call has been released. The Release
Reason can be displayed as Simple or Detailed text. When the
default
None
is selected, no release reasons appear on the set.
Release Reasons can be programmed under System prgrming.
With the display showing
System prgming
.
1. Press
‘
until the display shows
Release reasons
.
2. Press
≠
. The display shows
Text: None.
3. Select the text to be displayed as
Simple
or
Detailed
.
Note:
If you selected Simple text, press
‘
for Cause
code. The
Cause code
is for diagnostics. Make sure it
is set to
N
.