The following table describes the five types of loss packages.
Signal
Select the signal type for the line.
Press
CHANGE
to select one of these settings:
WinkStart
,
Immediate
,
DelayDial
.
Loss
Pkg
Receive
Loss
Transmit
Loss
Impedance
Distance to switch/
cable loss/terminating
switch
ShortCO
0 dB
3 dB
Short
Short/<2 dB/ICS to CO
MediumCO
0 dB
0 dB
TIA/EIA 464
Medium/>2 dB and <6 dB/
ICS to CO
LongCO
-3 dB
0 dB
TIA/EIA 464
Long/>6 dB/ICS to CO
ShortPBX
0 dB
0 dB
Short
Short/<2 dB/ICS to PBX
LongPBX
-3 dB
0 dB
TIA/EIA 464
Long/>2 dB/ICS to PBX
Tips -
This setting applies only to lines connected to an
NT7B75GA-93 Loop Start Trunk Cartridge.
When measuring the distance from ICS to CO and ICS to
PBX, use 600 ohms as the termination resistance setting.
Tips -
The Signal setting appears on the display only for
E&M or DID lines.
Make sure that this matches the signal type programmed for
the trunk at the other switch.
For E&M and DID lines connected to a DTI, the
Immediate
setting does not appear if dial mode for the line is set to
Tone
.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...