/ Problems with lines
Modular ICS 7.1 Installer Guide
N0130943 02
Problems with lines
The troubleshooting problems listed here focus on trouble
with making calls or using lines. For problems which are
specific to BRI lines, refer to
Problems with BRI service
on
page 615.
Calls cannot be made (but can be received)
1. Press
≤•‚
.
2. Press a line button.
3. If an incorrect line number or name appears, or if neither
appears, on the display, check the programming settings.
OR
If the correct line number or name appears on the display,
make sure the external lines are properly cross-connected.
4. Check external lines by attaching a test telephone directly
on the distribution block.
5. Ensure that the 25-pair cable is properly connected to the
modules or the ICS.
6. Run a Maintenance session.
7. Use
Module status
to verify that the module on which
the Trunk Cartridge is installed is not disabled or
unequipped.
8. Run a Maintenance session and disable the appropriate
ports using
Port/DN status
.
Charts showing external line port number defaults appear
under
Wiring charts
on page 260.
9. Enable the appropriate ports using
Port/DN status
.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...