617
N0130943 02
Modular ICS 7.1 Installer Guide
Possible problem
The card is not recognized by the ICS.
Solution
1. Verify that an Expansion Cartridge with Clocking, or
Clocking Cartridge is installed in the ICS.
2. Replace the card with another card of the same type.
Caller hears one ring and then a fast busy signal
when placing a call on a BRI line
Possible problem
CACH or EKTS, which are not supported by Modular ICS, is
included in the ISDN services package.
Solution
1. Contact your service provider and ensure that CACH or
EKTS are not part of the ISDN services package. These
services must be turned off at the switch.
2. Verify that the network DNs have been programmed
correctly, and verify the numbers with your service
provider.