Alarm codes /
551
N0130943 02
Modular ICS 7.1 Installer Guide
Alarm troubleshooting
Refer to the previous table before following these procedures.
Alarm: 10
1. Check to see if there is a device connected to the ICS (that
has a port number beginning with the number 1).
2. If there are no devices connected to the ICS, connect one
and then press
CLEAR
.
3. If there are any devices connected to the ICS, check all the
wiring associated with the devices.
4. Refer to
Problems with BRI service
on page 615.
Alarm: 37
1. Check that the BRI Card is properly installed.
2. Remove and re-install the BRI Card.
3. If the alarm persists, replace the BRI Card with another
BRI Card of the same type.
Alarm: 40 to Alarm: 47
1. Check the System Network evt log for events in the range
315-336 to verify the frequency of the alarms.
2. Refer to
Digital Trunk Interface trouble
on page 612.