476
/ System prgrming
Modular ICS 7.1 Installer Guide
N0130943 02
be allowed. Calls will not be allowed if they exceed the
maximum value for that service type or if they will use lines
needed to maintain the minimum value of other service types.
The summation of the minimum values for incoming or
outgoing PRI services cannot exceed the total number of lines
in the PRI pool.
The maximum value for an incoming or outgoing PRI service
cannot exceed the total number of lines in the PRI pool.
Programming Call by Call Limits
With the card set to
PRI
and the display showing
System
prgming
.
1. Press
≠
.The display shows
Hunt groups
.
2. Press
‘
until the display shows
CbC limits
.
3. Press
≠
.The display shows the first pool (PRI-A,
PRI-B, PRI-C, or PRI-D) that supports CbC routing.
4. Press
NEXT
to show the other pool, if it is available.
5. Press
≠
.The display shows
Service:
.
The service that is displayed depends upon the protocol.
6. Press
NEXT
to select a different service.
7. Press
≠
. If it applies, the display shows
Min incoming:2
.
8. Press
CHANGE
to enter a different number.
9. Press
‘
. If it applies, the display shows
Max incoming:23
.
10. Press
CHANGE
to enter a different number.
11. Press
‘
. The display shows
Min outgoing:4
.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...