606
/ Problems with optional equipment
Modular ICS 7.1 Installer Guide
N0130943 02
Problems with optional
equipment
Analog Terminal Adapter
1. Check the connections to the jack.
2. Check the connections to the ATA.
3. Disconnect the ATA and replace it with a working
telephone. If the telephone still works properly, the ICS
and/or the station modules (SM) are operating properly.
4. Verify that the programming has been done as described in
the
Programming Record
and the
Norstar Analog
Terminal Adapter Installation Card
.
5. If the trouble seems to be in the ICS or SM, double-check
all wiring and programming options. Also refer to
Problems with BRI service
on page 615 or
Data Module
down
on page 620.
OR
If the trouble seems to be with the ATA, disable the ATA
and replace it with a known working one.
Running a Maintenance session to test an ATA
1. Run a Maintenance session to ensure that the ATA is not
disabled. See
Port/DN status
on page 530.
2. Disable the port connected to the ATA using
Port/DN status
.
3. Enable the port connected to the ATA using
Port/DN status
.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...