280
/ Connecting the wiring
Modular ICS 7.1 Installer Guide
N0130943 02
T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec-
tions are non-polarized.
For an explanation about port numbering, see
Port numbering on the wiring charts
on page 260.
Note: Central Answering Positions (CAPs) that require a station auxiliary power supply (SAPS) must be connected with
a four-wire cord, as the SAPS is connected to the second wire pair. This includes any 7324 digital phone and CAP mod-
ule combination, and any 7316E digital phone attached to more than 4 KIMs. Refer to the SAPS installation card for de-
tailed installation instructions.
Nortel Networks Digital Mobility Controller 080/085 only require a maximum of eight pairs on a digital connector. The
remaining pairs can be connected to other digital system telephones.
21
Blue-Violet
----
----
no connection
47
Violet-Orange
----
----
no connection
22
Orange-Violet
----
----
no connection
48
Violet-Green
----
----
no connection
23
Green-Violet
----
----
no connection
49
Violet-Brown
----
----
no connection
24
Brown-Violet
----
----
no connection
50
Violet-Slate
----
----
no connection
25
Slate-Violet
----
----
no connection
Loop Start or CI Trunk Cartridge wiring chart
TC Slot
Pin
Wire color
Port
Service
Line
Slot 1
26
White-Blue
X01
T
1
1
Blue-White
X01
R
1
27
White-Orange
X02
T
2
2
Orange-White
X02
R
2
28
White-Green
----
No connection
----
3
Green-White
----
No connection
----
29
White-Brown
----
No connection
----
4
Brown-White
----
No connection
----
30
White-Slate
X03
T
3
5
Slate-White
X03
R
3
31
Red-Blue
X04
T
4
6
Blue-Red
X04
R
4
32
Red-Orange
----
No connection
----
7
Orange-Red
----
No connection
----
33
Red-Green
----
No connection
----
8
Green-Red
----
No connection
----
Slot 2
34
Red-Brown
X05
T
5
9
Brown-Red
X05
R
5
35
Red-Slate
X06
T
6
10
Slate-Red
X06
R
6
36
Black-Blue
----
No connection
----
11
Blue-Black
----
No connection
----
37
Black-Orange
----
No connection
----
Station Module wiring chart (Continued)
Pin
Wire color
Port
Service
Telephones SM
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...