Working with fractional PRI
Installer password required
When you purchase PRI from your service provider, you can
request the number of B-channels that are allocated for you to
use. For example, you may want to use only 12 B-channels
instead of 23 B-channels. If this is your situation, you should
disable all the B-channels that you do not need.
It is recommended that the number of lines that are
deprovisioned on a DTI card (configured as PRI) be the same
as the number of B-channels that are disabled. For example
when B-channels 13-23 are disabled, you should deprovision
lines 13 to 23.
Start with the display showing
Maintenance
1. Press
≠
.
System version
displays.
2. Press
‘
until you find
Link status
.
3. Press
≠
.
Cards on KSU
displays.
4. Press
≠
.
Cd1-KSU: PRI
displays.
5. Press
≠
.
B channel
displays.
6. Press
≠
. You can view the status of the PRI
channel, for example:
PRI:B01 Idle
.
Note:
When the display shows
PRI:B01 Near,
it means that
the channel has been disabled by Norstar.
When the display shows
PRI:B01 Far
, it means that
the channel has been disabled by the CO.
7. Press
Enable
or
Disable
key to change the setting for the
channel or press
‘
to move to the next
B-channel.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...