4. HOW TO USE THE POINT TABLE
4 - 12
4.2.2 Automatic operation using point table
(1) Absolute value command method
This method allows to select absolute value command or incremental value command with the auxiliary
function of the point table.
(a) Point table
Set the point table values using MR Configurator2 or the operation section.
Set the position data, servo motor speed, acceleration time constant, deceleration time constant,
dwell and auxiliary function to the point table.
To use the point table under the absolute value command method, set "0", "1", "8", or "9" to the
auxiliary function. To use the point table under the incremental value command method, set "2", "3",
"10", or "11" to the auxiliary function.
When you set a value outside this range to the point table, the set value will be clamped with the
maximum or minimum value. When changing the command unit or the connected motor results in
the set value outside this range, [AL. 37] will occur.
Item Setting
range Unit
Description
Position data
-999999 to 999999
(Note 1)
×10
STM
μ
m
×10
(STM-4)
inch
×10
-3
degree
pulse
(1) When using this point table under the absolute value command method
Set the target address (absolute value).
The teaching function is available for setting this value.
(2) When using this point table under the incremental value command method
Set the travel distance. A "-" sign indicates a reverse rotation command.
The teaching function is not available. When teaching is executed, the
setting will not be completed.
Servo motor
speed
0 to permissible
speed
r/min
mm/s (Note 2)
Set the command speed of the servo motor for execution of positioning.
The setting value must be within the permissible instantaneous speed of the
servo motor used.
Acceleration
time constant
0 to 20000
ms
Set a time until the servo motor rotates at the rated speed.
Deceleration
time constant
0 to 20000
ms
Set a time from when the servo motor rotates at the rated speed until when
the motor stops.
Dwell
0 to 20000
ms
Set the dwell.
To disable the dwell, set "0" or "2" to the auxiliary function.
To perform varying-speed operation, set "1", "3", "8", "9", "10" or "11" to the
auxiliary function and 0 to the dwell.
When the dwell is set, the position command of the selected point table is
completed, and after the set dwell has elapsed, the position command of the
next point table is started.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...