4. HOW TO USE THE POINT TABLE
4 - 10
(b) Incremental value command method
As position data, set the travel distance from the current address to the target address.
1) Millimeter, inch, and pulse unit
Setting range: 0 to 999999 [×10
STM
μ
m] (STM = Feed length multiplication [Pr. PT03])
0 to 999999 [×10
(STM-4)
inch] (STM = Feed length multiplication [Pr. PT03])
0 to 999999 [pulse]
Current address
Target address
Position data = |Target address - Current address|
2) Degree unit
Target address
Here, Travel distance = -170 degrees
Position data = Travel distance from current address to target address
270 degrees
80 degrees
0 degree
Current address