4. HOW TO USE THE POINT TABLE
4 - 25
(c) Varying-speed operation
By setting the auxiliary function of the point table, the servo motor speed during positioning can be
changed. Point tables are used by the number of the set speed.
1) Absolute value command method ([Pr. PT01] = _ _ _ 0)
Set "1" or "3" to the auxiliary function to execute the positioning at the speed set in the following
point table.
At this time, the position data selected at start is valid, and the acceleration/deceleration time
constant set in the next and subsequent point tables is invalid.
By setting "1" or "3" to sub functions until point table No. 254, the operation can be performed at
maximum 255 speeds.
Always set "0" or "2" to the auxiliary function of the last point table.
To perform varying-speed operation, always set "0" to the dwell.
Setting "1" or more will enables the automatic continuous positioning operation.
The following table shows an example of setting.
Point table
No.
Dwell [ms]
(Note 1)
Auxiliary function
Varying-speed operation
1 0 1
Consecutive point table data
2 0 3
3
Disabled
0 (Note 2)
4 0 3
Consecutive point table data
5 0 1
6
Disabled
2 (Note 2)
Note 1. Always set "0".
2.
Always set "0" or "2" to the auxiliary function of the last point table among the
consecutive point tables.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...