6. HOW TO USE INDEXER
6 - 4
6.1.4 Parameter setting
POINT
The following encoder cables are of four-wire type. When using any of these
encoder cables, set [Pr. PC22] to "1 _ _ _" to select the four-wire type. Incorrect
setting will result in [AL. 16 Encoder initial communication error 1].
MR-EKCBL30M-L
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
In the indexer method, assign the following input device to CN1-18 pin with [Pr.
PD10].
CN1-18: MD1 (Operation mode selection 2)
Assign the following output devices to the CN1-22, CN1-23, and CN1-25 pins
with [Pr. PD23], [Pr. PD24], and [Pr. PD26].
CN1-22: CPO (Rough match)
CN1-23: ZP (Home position return completion)
CN1-25: MEND (Travel completion)
When using this servo in the indexer method, set [Pr. PA01] to "_ _ _ 8" (Positioning mode (indexer
method)). For the indexer method, the servo can be used by merely changing the basic setting parameters
([Pr. PA _ _ ]) and positioning control parameters ([Pr. PT _ _ ]) mainly.
As necessary, set other parameters.
The following table shows [Pr. PA _ _ ] and [Pr. PT _ _ ] settings required for the indexer method.
Operation mode selection item
Operation mode
Parameter setting
Input device setting
[Pr. PA01]
[Pr. PT04]
(Note 2)
[Pr. PT27]
MD0
(Note 1)
MD1
(Note 1
,
3)
DI0 to DI7 (Note 1)
Automatic operation
mode
Automatic operation
mode 1
(Rotation direction
specifying indexer)
_ _ _ 8
Off On
Set any next station
No. (Refer to section
6.2.2 (3).)
Automatic operation
mode 2 (Shortest
rotating indexer)
On On
Manual operation
mode
Station JOG
operation
_ _ 0 _
On Off
Any
JOG operation
_ _ 1 _
Home position
return mode
Dog type/Torque limit
changing dog type
_ _ _ 0
Off Off
Any
Data set type/torque
limit changing data
set type
_ _ _ 2
Note 1. MD0: Operation mode selection 1, MD1: Operation mode selection 2, DI0 to DI7: Next station No. selection 1 to 8
2. Setting other than "_ _ _ 0" and "_ _ _ 2" will trigger [AL. 37 Parameter error].
3. In the indexer method, assign the following input device to CN1-18 pin with [Pr. PD10].
CN1-18: MD1 (Operation mode selection 2)
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...