11. MR-D01 EXTENSION I/O UNIT
11 - 68
(3) Timing chart
5 ms or longer
ON
OFF
RD (Ready)
ON
OFF
MEND (Travel completion)
ON
OFF
CPO (Rough match)
ON
OFF
INP (In-position)
Servo motor speed
Forward
rotation
0 r/min
3 ms or less
Position 1 + Speed 1
ON
OFF
MD0 (Automatic/manual
selection)
ON
SON (Servo-on)
ON
OFF
STRB (Strobe)
Position data BCD
(3 digits × 2)
SPD1 (Speed selection 1) to
SPD4 (Speed selection 4)
Speed 1 (Note 3)
Position 1
lower 3 digits
Position 1
upper 3 digits
OFF
ON
OFF
ST1 (Forward rotation start)
(Note 1)
5 ms or
longer
5 ms or
longer
4 ms or longer (Note 2)
ON
OFF
ON
OFF
PRQ1 (Position data
request 1) (Note 4)
PRQ2 (Position data
request 2) (Note 5)
5 ms or
longer
5 ms or longer
(Note 2)
3 ms or longer (Note 2)
Note 1. In the incremental value command method, ST2 (Reverse rotation start) can be used. In this case, the timing chart is the
same as the one for ST1.
2. The detection of external input signals is delayed by the time set in the input filter setting of [Pr. PD29]. Considering the
output signal sequence from the controller and signal variations due to hardware, configure a sequence that changes the
position data earlier.
3. The speed command selected in Speed selection 1 (SPD1) to 4 (SPD4)
4. This signal is off when the power is on.
5. This signal is on when the power is on.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...