8. TROUBLESHOOTING
8 - 9
No. Name
Detail
No.
Detail name
Stop
Type
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
CN1-22
(Bit 2)
CN1-23
(Bit 1)
CN1-24
(Bit 0)
Alarm
7B.1
Encoder diagnosis error 1
(safety observation function)
DB
7B
Encoder diagnosis
error (safety
observation function)
7B.2
Encoder diagnosis error 2
(safety observation function)
DB
1 1 0
7B.3
Encoder diagnosis error 3
(safety observation function)
DB
7B.4
Encoder diagnosis error 4
(safety observation function)
DB
7C
Functional safety
unit communication
diagnosis error
(safety observation
function)
7C.1
Functional safety unit
communication setting error
(safety observation function)
SD
(Note 5)
0 0 0
7C.2
Functional safety unit
communication data error
(safety observation function)
SD
(Note 5)
7D
Safety observation
error
7D.1 Stop observation error
DB
(Note 3)
1 1 1
7D.2 Speed observation error
DB
(Note 5)
82
Master-slave
operation error 1
82.1 Master-slave operation error 1
EDB
Network module
initialization error
84.1
Network module undetected
error
DB
84
84.2
Network module initialization
error 1
DB
84.3
Network module initialization
error 2
DB
Network module
error
85.1 Network module error 1
SD
85
85.2 Network module error 2
SD
85.3 Network module error 3
SD
Network
communication error
86.1 Network communication error 1
SD
86
86.2 Network communication error 2
SD
86.3 Network communication error 3
SD
8A
USB
communication
time-out error/serial
communication
time-out
error/Modbus-RTU
communication
time-out error
8A.1
USB communication time-out
error/Serial communication
time-out error
SD
0 0 0
8A.2
Modbus-RTU communication
time-out error
SD
8D
CC-Link IE
communication error
8D.1
CC-Link IE communication error
1
SD
8D.2
CC-Link IE communication error
2
SD
8D.3 Master station setting error 1
DB
8D.5 Master station setting error 2
DB
8D.6
CC-Link IE communication error
3
SD
8D.7
CC-Link IE communication error
4
SD
8D.8
CC-Link IE communication error
5
SD
8D.9 Synchronization error 1
SD
8D.A Synchronization error 2
SD
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...