4. HOW TO USE THE POINT TABLE
4 - 69
4.4.15 Precautions for using linear servo motors
POINT
The incremental linear encoder and the absolute position linear encoder have
different reference home positions at the home position return.
(1) Incremental linear encoder
CAUTION
If the resolution or the stop interval (the third digit of [Pr. PL01]) of the linear
encoder is large, it is very dangerous since the linear servo motor may crash into
the stroke end.
(a) When the linear encoder home position (reference mark) exists in the home position return direction
When an incremental linear encoder is used, the home position is the position per 1048576 pulses
(changeable with the third digit of [Pr. PL01]) with reference to the linear encoder home position
(reference mark) passed through first after a home position return start. Change the setting value of
[Pr. PL01] according to the linear encoder resolution.
[Pr. PL01]
Stop interval setting at the home position return
Setting
value
Stop interval [pulse]
0
8192
1
131072
2
262144
3
1048576 (initial value)
4
4194304
5
16777216
6
67108864
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...