5. HOW TO USE THE PROGRAM
5 - 23
(f) External pulse count (COUNT)
When the number of input pulses of the manual pulse generator becomes larger than the value set
for the "COUNT" command, the next step is executed. Setting "0" clears cumulative input pulses.
Command Description
COUNT (500)
Wait for the next step until the number of input pulses of the manual pulse generator reaches 500
[pulse]. a)
SPN (500)
Servo motor speed
500 [r/min]
STA (200)
Acceleration time constant
200 [ms]
STB (300)
Deceleration time constant
300 [ms]
MOV (1000)
Absolute value travel command
1000 [×10
STM
μ
m]
TRIP (500)
Trip point specification
500 [×10
STM
μ
m] b)
COUNT (0)
Clear cumulative input pulses.
c)
STOP Program
stop
c) Clear cumulative input pulses.
b) 500 [×10
STM
μ
m]
Manual pulse generator
Cumulative input pulses
a) 500 [pulse]
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...