12. APPLICATION OF FUNCTIONS
12 - 39
12.1.11 Stop operation of cam control
If one of the following stop causes occurs on the output axis during cam control, the cam control stops after
the output axis is stopped. (CAMS turns off.)
To restart the cam control, adjust the synchronous position of the output axis.
Stop cause
Command stop processing
Remark
Software stroke limit detection
Instantaneous stop
Refer to (1).
Stroke limit detection
Instantaneous stop
Refer to (1).
Stop due to forced stop 1 or 2, or alarm
occurrence
Instantaneous stop or
deceleration to a stop
Stop due to base circuit shut-off Refer to (1).
Stop by the forced stop deceleration function Refer to
(2).
Cam control command (CAMC) OFF
Instantaneous stop
Refer to (1).
Servo-off
Instantaneous stop
Coasting state
(1) Instantaneous stop
The operation stops without deceleration. The servo amplifier immediately stops the command.
Cam axis one cycle current value
Feed current value
Feed speed
t
t
t
Instantaneous stop
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...