3. DISPLAY AND OPERATION SECTIONS
3 - 22
(b) Parameters of 6 or more digits
The following example gives the operation procedure to change the electronic gear numerator to
"123456" with [Pr. PA06 Electronic gear numerator].
The screen flickers.
Press the "MODE" button to switch to the basic setting parameter screen.
Press the "UP" or "DOWN" button to select [Pr. PA06].
Press the "SET" button once.
Press the "SET" button
once.
Setting of upper 1 digit
Change the setting with
the "UP" or "DOWN"
button.
Press the "SET" button
once.
Enter the setting.
Press the "MODE" button
once.
Press the "MODE" button
once.
Setting of lower 4 digits
……
……
……
…