7. PARAMETERS
7 - 35
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PB19
VRF11
Vibration
suppression
control 1 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 1 to suppress
low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ _ 2)" is selected, the setting written to the parameter is used. For details,
refer to section 7.1.5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
Setting range: 0.1 to 300.0
100.0
[Hz]
PB20
VRF12
Vibration
suppression
control 1 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 1 to suppress
low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ _ 2)" is selected, the setting written to the parameter is used. For details,
refer to section 7.1.5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
Setting range: 0.1 to 300.0
100.0
[Hz]
PB21
VRF13
Vibration
suppression
control 1 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ _ 2)" is selected, the setting written to the parameter is used. For details,
refer to section 7.1.5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
Setting range: 0.00 to 0.30
0.00
PB22
VRF14
Vibration
suppression
control 1 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ _ 2)" is selected, the setting written to the parameter is used. For details,
refer to section 7.1.5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
Setting range: 0.00 to 0.30
0.00
PB23
VFBF
Low-pass
filter selection
_ _ _ x Shaft resonance suppression filter selection
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine resonance suppression filter 4
selection" in [Pr. PB49], the shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PB24
*MVS
Slight
vibration
suppression
control
_ _ _ x Slight vibration suppression control selection
Select the slight vibration suppression control.
0: Disabled
1: Enabled
To enable the slight vibration suppression control, select "Manual mode (_ _ _ 3)" of
"Gain adjustment mode selection" in [Pr. PA08].
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...