5. HOW TO USE THE PROGRAM
5 - 35
(4) Timing chart
ON
OFF
RD (Ready)
ON
OFF
ALM (Malfunction)
ON
OFF
Servo motor speed
SON (Servo-on)
Forward rotation
0 r/min
Reverse rotation
PED
(Position end)
MD0
(Operation mode selection 1)
ON
OFF
ON
OFF
ON
OFF
ST1 (Forward rotation start)
ST2 (Reverse rotation start)
Forward rotation JOG
ON
OFF
Reverse rotation JOG
80 ms
5.3.2 Manual pulse generator operation
(1) Setting
POINT
To enhance noise tolerance, set "_ 2_ _" to [Pr. PA13] when the command
pulse frequency is 500 kpulses/s or less, or set "_ 3 _ _" to [Pr. PA13] when the
command pulse frequency is 200 kpulses/s or less.
According to the purpose of use, set input signals and parameters as shown below. In this case, DI0
(Program No. selection 1) to DI7 (Program No. selection 8) are invalid.
Item Setting
method
Setting
Manual operation mode
selection
MD0 (Operation mode selection 1)
Switch off MD0.
Manual pulse generator
multiplication
[Pr. PT03]
Set the multiplication factor for the pulses
generated from the manual pulse generator.
For details, refer to (3) of this section.
Servo motor rotation direction [Pr. PA14]
Refer to (2) of this section.
Command input pulse train
input form
[Pr. PA13]
Set "_ _ _ 2" (A/B-phase pulse train).
Pulse train filter selection
[Pr. PA13]
Set other than "_ 0 _ _" and "_ 1 _ _".
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...