7. PARAMETERS
7 - 17
7.2.1 Basic setting parameters ([Pr. PA_ _ ])
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PA01
*STY
Operation
mode
_ _ _ x Control mode selection
Select a control mode.
0 to 5: Not used for positioning mode.
6: Positioning mode (point table method)
7: Positioning mode (program method)
8: Positioning mode (indexer method)
0h
_ _ x _ Operation mode selection
0: Standard control mode
1: Fully closed loop control mode
4. Linear servo motor control mode
6: DD motor control mode (except 400 V class servo amplifiers)
The following settings will trigger [AL. 37 Parameter error].
A value is set other than "0", "1", "4", and "6" to this digit.
"1" or "4" is set to this digit with the indexer method.
"1" or "4" is set to this digit when "Position data unit" is set to [degree] in [Pr. PT01].
For MR-J4-03A6-RJ servo amplifiers, this digit cannot be used other than the initial
value.
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
1h
PA02
*REG
Regenerative
option
_ _ x x Regenerative option
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 37
Parameter error] occurs.
00: Regenerative option is not used.
For the servo amplifiers of 100 W, a regenerative resistor is not used.
For servo amplifier of 0.2 kW to 7 kW, built-in regenerative resistor is used.
Supplied regenerative resistors or regenerative option is used with the servo
amplifier of 11 kW to 22 kW.
01: FR-RC-(H)/FR-CV-(H)/FR-BU2-(H)
When you use FR-RC-(H) or FR-CV-(H), select "Mode 2 (_ _ _ 1)" of
"Undervoltage alarm detection mode selection" in [Pr. PC27].
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required.)
08: MR-RB31
09: MR-RB51 (Cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (Cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (Cooling fan is required.)
82: MR-RB3G-4 (Cooling fan is required.)
83: MR-RB5G-4 (Cooling fan is required.)
84: MR-RB34-4 (Cooling fan is required.)
85: MR-RB54-4 (Cooling fan is required.)
91: MR-RB3U-4 (Cooling fan is required.)
92: MR-RB5U-4 (Cooling fan is required.)
FA: When the supplied regenerative resistors or the regenerative option is cooled by
the cooling fan to increase the ability with the servo amplifier of 11 kW to 22 kW.
For MR-J4-03A6-RJ servo amplifiers, this digit cannot be used other than the initial
value.
00h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...