6. HOW TO USE INDEXER
6 - 9
(2) Other parameter settings
(a) Setting assignment direction of station No.
Select an assignment direction of station No. with [Pr. PA14].
CW
CCW
[Pr. PA14] setting
Servo motor rotation direction
ST1 (Forward rotation start) is on.
0
Next station No. will be assigned in CW direction in order of
1, 2, 3…
1
Next station No. will be assigned in CCW direction in order
of 1, 2, 3…
Station No.
1
2
3
4
CW direction
Station No.
1 2
3 4
CCW direction
[Pr. PA14]: 0 (initial value)
[Pr. PA14]: 1
(b) Setting number of stations
Set a number of stations to [Pr. PT28].
[Pr. PT28] setting
Number of
stations
2 3 4
255
Station No.
No. 0
No. 1
No. 2
No. 1
No. 0
No. 3
No. 0
No. 1
No. 2
No. 0 No. 254