3. DISPLAY AND OPERATION SECTIONS
3 - 49
3.2.7 External I/O signal display
POINT
The I/O signal settings can be changed using I/O setting parameters [Pr. PD04]
to [Pr. PD28].
The on/off states of the digital I/O signals connected to the servo amplifier can be confirmed.
(1) Operation
The display at power-on. Use the "MODE" button to display the diagnostic screen.
Press the "UP" button twice.
…… External I/O signal display screen
(2) Display definition
The 7-segment LED segments and CN1 connector pins correspond as shown below.
Input signals
Output signals
CN1-35/
CN1-38
CN1-15
CN1-43
CN1-49
CN1-23
Light on: on
Light off: off
CN1-16
CN1-19
CN1-22
CN1-17
CN1-45
CN1-48
CN1-33
CN1-10/
CN1-37
CN1-42
CN1-25
CN1-18
CN1-41
CN1-44
CN1-24
The LED segment corresponding to the pin is lit to indicate on, and is extinguished to indicate off. The
decimal point in the second digit flickers continuously.
For each pin signal in control modes, refer to section 2.2 (2).
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...