4.4.6 Home position ignorance (servo-on position as home position)
POINT
When you perform this home position return, it is unnecessary to switch to the
home position return mode.
The position at servo-on is used as the home position.
(1) Device/parameter
Set input devices and parameters as follows.
Item Used
parameter
Setting
Home position ignorance
[Pr. PT04]
_ _ _ 4: Select the home position ignorance.
Home position return position
data
[Pr. PT08]
Set the current position at the home position
return completion.
(2) Timing chart
ON
OFF
RD (Ready)
ON
OFF
MEND
(Travel completion)
ON
OFF
CPO
(Rough match)
ZP
(Home position return
completion)
ON
OFF
Forward rotation
0 r/min
Reverse rotation
SON (Servo-on)
Servo motor
speed
Home position return position data
ON
OFF
The setting value of [Pr. PT08 Home position return position data] is used as the position address at the
home position return completion.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...