7. PARAMETERS
7 - 70
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PE45
LMCN
Lost motion
compensation
negative-side
compensation
value
selection
Set the lost motion compensation for when forward rotation (CCW) switches to
reverse rotation (CW) in increments of 0.01% assuming the rated torque as 100%.
This parameter is available with servo amplifiers with software version B4 or later.
Setting range: 0 to 30000
0
[0.01%]
PE46
LMFLT
Lost motion
filter setting
Set the time constant of the lost motion compensation filter in increments of 0.1 ms.
If the time constant is "0", the torque is compensated with the value set in [Pr. PE44]
and [Pr. PE45]. If the time constant is other than "0", the torque is compensated with
the high-pass filter output value of the set time constant, and the lost motion
compensation will continue.
This parameter is available with servo amplifiers with software version B4 or later.
Setting range: 0 to 30000
0
[0.1 ms]
PE47
TOF
Torque offset
Set this when canceling unbalanced torque of vertical axis. Set this assuming the
rated torque of the servo motor as 100%. The torque offset does not need to be set for
a machine not generating unbalanced torque. The torque offset cannot be used for
linear servo motors and direct drive motors. Set 0.00%.
This parameter is available with servo amplifiers with software version B4 or later.
Setting range: -10000 to 10000
0
[0.01%]
PE48
*LMOP
Lost motion
compensation
function
selection
_ _ _ x Lost motion compensation selection
0: Disabled
1: Enabled
This parameter is available with servo amplifiers with software version B4 or later.
0h
_ _ x _ Unit setting of lost motion compensation non-sensitive band
0: 1 pulse unit
1: 1 kplulse unit
This parameter is available with servo amplifiers with software version B4 or later.
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PE49
LMCD
Lost motion
compensation
timing
Set the lost motion compensation timing in increments of 0.1 ms.
You can delay the timing to perform the lost motion compensation for the set time.
This parameter is available with servo amplifiers with software version B4 or later.
Setting range: 0 to 30000
0
[0.1 ms]
PE50
LMCT
Lost motion
compensation
non-sensitive
band
Set the lost motion compensation non-sensitive band. When the fluctuation of the
droop pulse is the setting value or less, the speed will be 0. Setting can be changed in
[Pr. PE48]. Set the parameter per encoder unit.
This parameter is available with servo amplifiers with software version B4 or later.
Setting range: 0 to 65535
0
[pulse]/
[kpulse]
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...