4. HOW TO USE THE POINT TABLE
4 - 30
Example 2. Operations when "9" is set to the auxiliary function of point table No. 3
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
1 0.00
3000
100
150
100 1
05
2 5.00
2000
150
200
200
1 10
3 15.00
1000
300
100 150
9
15
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 3
3) Executing point table No. 1 when "9" is set to the auxiliary function of point table No. 3
4) Repeating the above execution in the sequence of 1) to 2) to 3) to 1) to 2) to 3)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
Position address
Point table No. to select
ST1 (Forward rotation start)
ON
OFF
PT0 (Point table No. output 1)
to PT7 (Point table No. output 8)
(Note)
M code output (Note)
Speed
(2000)
Point table No. 2
Speed (1000)
Point table No. 3
Point table No. 1
5.00
1)
2)
3)
0
5.00
15.00
2
Speed
(3000)
Note. PT0 to PT7 and M code are not outputted in automatic continuous operation.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...