4. HOW TO USE THE POINT TABLE
4 - 44
4.3.2 Manual pulse generator operation
(1) Setting
POINT
To enhance noise tolerance, set "_ 2 _ _" to [Pr. PA13] when the command
pulse frequency is 500 kpulses/s or less, or set "_3_ _" to [Pr. PA13] when the
command pulse frequency is 200 kpulses/s or less.
According to the purpose of use, set input devices and parameters as shown below. In this case, DI0
(Point table No. selection 1) to DI7 (Point table No. selection 8) are invalid.
Item
Device/parameter to be used
Setting
Manual operation mode
selection
MD0 (Operation mode selection 1)
Switch off MD0.
Manual pulse generator
multiplication
[Pr. PT03]
Set the multiplication factor for the pulses
generated from the manual pulse generator.
For details, refer to (3) of this section.
Servo motor rotation direction [Pr. PA14]
Refer to (2) of this section.
Command input pulse train
input form
[Pr. PA13]
Set "_ _ _ 2" (A/B-phase pulse train).
Pulse train filter selection
[Pr. PA13]
Set other than "_ 0 _ _" and "_ 1 _ _".
(2) Servo motor rotation direction
[Pr. PA14] setting
Servo motor rotation direction
Manual pulse generator operation:
forward rotation
Manual pulse generator operation:
reverse rotation
0 CCW
rotation
CW
rotation
1
CW rotation
CCW rotation
CW
CCW
Forward rotation
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...