7. PARAMETERS
7 - 62
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PD29
*DIF
Input filter
setting
Select a filter for the input signal.
_ _ _ x Input signal filter selection
If external input signal causes chattering due to noise, etc., input filter is used to
suppress it.
0: None
1: 0.888 [ms]
2: 1.777 [ms]
3: 2.666 [ms]
4: 3.555 [ms]
5: 4.444 [ms]
6: 5.333 [ms]
4h
_ _ x _ RES (Reset) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
0h
_ x _ _ CR (Clear) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
0h
x _ _ _ For manufacturer setting
0h