11. MR-D01 EXTENSION I/O UNIT
11 - 53
(b) OVR (Analog override selection)
Enable or disable OVC (Analog override).
Analog
override
OVR (Analog override selection)
OVC (Analog override)
-10 V to +10 V
Servo
motor
Servo amplifier
Position
control
Speed
control
Select a changed value by using OVR (Analog override selection).
(Note) External input
signal
Speed change value
0 No
change
1
Setting of OVC (Analog override) is
enabled.
Note. 0: Off
1: On
(c) Analog override offset ([Pr. Po21])
You can set an offset voltage to the input voltage of OVC (Analog override) with [Pr. Po21]. The
setting value ranges from -9999 to +9999 [mV].