2. SIGNALS AND WIRING
2 - 35
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
CP/BCD
CL
PS
Mark detection
rising latch
completed
MSDH
Turning on MSD (Mark detection) will turn on MSDH.
DO-1
Mark detection
falling latch
completed
MSDL
After MSD (Mark detection) is turned on, turning off MSD will turn on
MSDL.
DO-1
Alarm code
ACD0 (CN1-24) To use these signals, set " _ _ _ 1" in [Pr. PD34].
This signal is outputted when an alarm occurs.
When an alarm is not occurring, respective ordinary signals are outputted.
For details of the alarm codes, refer to chapter 8.
When [Pr. PD34] is set to "_ _ _ 1", setting the following will trigger [AL. 37
Parameter error].
"_ _ _ 1" is set in [Pr. PA03] and the absolute position detection system
by DIO is selected.
MBR, DB, or ALM is assigned to the CN1-22 pin, CN1-23 pin, or CN1-24
pin.
DO-1
ACD1 (CN1-23)
ACD2 (CN1-22)
Variable gain
selection
CDPS
CDPS turns on during gain switching.
DO-1
Absolute position
undetermined
ABSV
ABSV turns on when the absolute position is undetermined.
DO-1
During tough
drive
MTTR
When a tough drive is "Enabled" in [Pr. PA20], activating the instantaneous
power failure tough drive will turn on MTTR.
This device is not available with MR-J4-03A6-RJ servo amplifiers.
DO-1
During fully
closed loop
control
CLDS
CLDS turns on during fully closed loop control.
This device is not available with MR-J4-03A6-RJ servo amplifiers.
DO-1
Under cam
control
CAMS
It turns on when the control switches to the cam control.
It turns off when the control switches to the normal positioning control.
DO-1
Cam position
compensation
execution
completed
CPCC
It turns on when the cam compensation execution is enabled.
It turns on when the position compensation is not being executed during
the cam control.
DO-1
Clutch on/off
status
CLTS
It turns on with clutch-on.
It is always off when [Cam control data No. 36 - Main shaft clutch control
setting] is set to "_ _ _ 0".
DO-1
Clutch
smoothing status
CLTSM
It outputs clutch smoothing status.
The output depends on the setting in [Cam control data No. 42 - Main shaft
clutch smoothing system] as follows:
0: Direct
Always off
1: Time constant method (index)
Always on in clutch-on status
It turns off when the clutch is off and the smoothing is complete.
DO-1
(2) Input signal
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
CP/BCD
CL
PS
Manual pulse
generator
PP
(CN1-10) Connect the manual pulse generator (MR-HDP01).
When using the signal, enable PP and NP with [Pr. PD44] and [Pr. PD46].
DI-2
NP (CN1-35)
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...