3. DISPLAY AND OPERATION SECTIONS
3 - 35
(2) Diagnosis display list
Name Display Description
Sequence
Not ready
Indicates that the servo amplifier is being initialized
or an alarm has occurred.
Ready
Indicates that initialization is completed, and the
servo amplifier is in servo-on state and ready to
operate.
Drive recorder enabled/disabled display
Drive recorder enabled
When an alarm occurs in this state, the drive
recorder will operate and record the status of
occurrence.
Drive recorder disabled
The drive recorder will not operate on the following
conditions.
1.The graph function of MR Configurator2 is being
used.
2.The machine analyzer function is being used.
3.[Pr. PF21] is set to "-1".
External I/O signal display
Refer to section 3.2.7.
This Indicates the on/off status of external I/O
signal.
Output signal (DO) forced output
This allows digital output signal to be switched
on/off forcibly.
Refer to section 3.2.8 for details.
Test operation mode
JOG operation
JOG operation can be performed when there is no
command from an external controller.
For details, refer to section 18.5.10 (2) of "MR-J4-
_A_(-RJ) Servo Amplifier Instruction Manual".
Positioning operation
Positioning operation can be performed when there
is no command from an external controller.
MR Configurator2 is required to perform positioning
operation.
For details, refer to section 4.5.9 (3) of "MR-J4-
_A_(-RJ) Servo Amplifier Instruction Manual".
Motor-less operation
Without connecting the servo motor, output signals
or status display can be provided in response to the
input device as if the servo motor is actually
running.
For details, refer to section 4.5.9 (4) of "MR-J4-
_A_(-RJ) Servo Amplifier Instruction Manual".
Machine analyzer
operation
Merely connecting the servo amplifier allows the
resonance point of the mechanical system to be
measured.
MR Configurator2 is required to perform machine
analyzer operation.
For details, refer to section 11.7 of "MR-J4-_A_(-RJ)
Servo Amplifier Instruction Manual".
For manufacturer
adjustment
This is for manufacturer adjustment.
Single-step feed
This function is available only in the point table
method and program method. When the positioning
operation is executed in accordance with the point
table or program set by MR Configurator2, the
diagnosis display changes to "d-6" during single-
step feed. For other control mode, the display does
not change to "d-6". Refer to section 3.2.9 for
details.
The status will be displayed with the "MODE"
button. The "UP" and "DOWN" buttons are disabled.
www.kavrammuhendislik.com.tr
Содержание MELSERVO MR-J4-03A6-RJ
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Страница 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Страница 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Страница 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Страница 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Страница 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Страница 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Страница 607: ...MEMO www kavrammuhendislik com tr ...