CP6923
Management Commands
Page 7 - 35
CP6923 CLI Reference Manual
7.9.12
show radius statistics
This command is used to display the statistics for RADIUS or configured server. To show the configured RADIUS
server statistic, the IP address or hostname specified must match that of a previously configured RADIUS server.
On execution, the following fields are displayed.
If you do not specify the IP address, then only Invalid Server Address field is displayed. Otherwise other listed fields
are displayed.
7.10
Commands
provides access control for networked devices via one or more centralized servers. Similar to RADIUS,
this protocol simplifies authentication by making use of a single database that can be shared by many clients on a
large network. is based on the TACACS protocol (described in RFC1492) but additionally provides for
separate authentication, authorization, and accounting services. The original protocol was UDP based with
messages passed in clear text over the network; uses TCP to ensure reliable delivery and a shared key
configured on the client and daemon server to encrypt all messages.
Format
show radius statistics
[<ipaddr|hostname>]
Mode
Privileged EXEC
Term
Definition
Invalid Server
Addresses or
Hostname
The number of RADIUS Access-Response packets received from unknown addresses.
Server IP Address /
Hostname
IP address or hostname of the Server.
Round Trip Time
The time interval, in hundredths of a second, between the most recent Access-Reply, Access-
Challenge and the Access-Request that matched it from the RADIUS authentication server.
Access Requests
The number of RADIUS Access-Request packets sent to this server. This number does not
include retransmissions.
Access
Retransmission
The number of RADIUS Access-Request packets retransmitted to this RADIUS
authentication server.
Access Accepts
The number of RADIUS Access-Accept packets, including both valid and invalid packets,
which were received from this server.
Access Rejects
The number of RADIUS Access-Reject packets, including both valid and invalid packets,
which were received from this server.
Access Challenges
The number of RADIUS Access-Challenge packets, including both valid and invalid packets,
which were received from this server.
Malformed Access
Responses
The number of malformed RADIUS Access-Response packets received from this server.
Malformed packets include packets with an invalid length. Bad authenticators or signature
attributes or unknown types are not included as malformed access responses.
Bad
Authenticators
The number of RADIUS Access-Response packets containing invalid authenticators or
signature attributes received from this server.
Pending Requests
The number of RADIUS Access-Request packets destined for this server that have not yet
timed out or received a response.
Timeouts
The number of authentication timeouts to this server.
Unknown Types
The number of RADIUS packets of unknown types, which were received from this server on
the authentication port.
Packets Dropped
The number of RADIUS packets received from this server on the authentication port and
dropped for some other reason.
Содержание CP6923
Страница 4: ...Page iv ...
Страница 35: ...Using the Command Line Interface Chapter 1 1 Page 1 1 CP6923 CLI Reference Manual CP6923 ...
Страница 44: ...Using the Command Line Interface CP6923 CP6923 CLI Reference Manual Page 1 10 ...
Страница 45: ...Switching Commands Chapter 1 2 Page 2 1 CP6923 CLI Reference Manual CP6923 ...
Страница 174: ...Switching Commands CP6923 CP6923 CLI Reference Manual Page 2 130 ...
Страница 175: ...Quality of Service Commands Chapter 1 3 Page 3 1 CP6923 CLI Reference Manual CP6923 ...
Страница 213: ...Routing Commands Chapter 1 4 Page 4 1 CP6923 CLI Reference Manual CP6923 ...
Страница 285: ...Multicast Commands Chapter 1 5 Page 5 1 CP6923 CLI Reference Manual CP6923 ...
Страница 314: ...Multicast Commands CP6923 CP6923 CLI Reference Manual Page 5 30 ...
Страница 315: ...Utility Commands Chapter 6 Page 6 1 CP6923 CLI Reference Manual CP6923 ...
Страница 387: ...Management Commands Chapter 1 7 Page 7 1 CP6923 CLI Reference Manual CP6923 ...
Страница 428: ...Management Commands CP6923 CP6923 CLI Reference Manual Page 7 42 ...
Страница 429: ...CP6923 Page A 1 CP6923 CLI Reference Manual Getting Help Appendix A ...
Страница 434: ...CP6923 Page B 1 CP6923 CLI Reference Manual FASTPATH log messages Appendix B ...
Страница 450: ...CP6923 Page C 1 CP6923 CLI Reference Manual List of Commands Appendix C ...