CP6923
Management Commands
Page 7 - 7
CP6923 CLI Reference Manual
7.2.5
show serial
This command displays serial communication settings for the switch.
7.3
Telnet Commands
This section describes the commands you use to configure and view Telnet settings. You can use Telnet to manage
the device from a remote management host.
7.3.1
ip telnet server enable
Use this command to enable Telnet connections to the system and to enable the Telnet Server Admin Mode. This
command opens the Telnet listening port.
7.3.1.1
no ip telnet server enable
Use this command to disable Telnet access to the system and to disable the Telnet Server Admin Mode. This
command closes the Telnet listening port and disconnects all open Telnet sessions.
7.3.2
telnet
This command establishes a new outbound Telnet connection to a remote host. The
host
value must be a valid IP
address or host name. Valid values for
port
should be a valid decimal integer in the range of 0 to 65535, where the
default value is 23. If
[debug]
is used, the current Telnet options enabled is displayed. The optional
line
parameter
Format
show serial
Modes
•
Privileged EXEC
•
User EXEC
Term
Definition
Serial Port Login
Timeout (minutes)
The time, in minutes, of inactivity on a Serial port connection, after which the Switch will close
the connection. Any numeric value between 0 and 160 is allowed, the factory default is 5. A
value of 0 disables the timeout.
Baud Rate (bps)
The default baud rate at which the serial port will try to connect. The available values are 1200,
2400, 4800, 9600, 19200, 38400,57600, and 115200 baud. The factory default is 9600 baud.
Character Size
(bits)
The number of bits in a character. The number of bits is always 8.
Flow Control
Whether Hardware Flow-Control is enabled or disabled. Hardware Flow Control is always
disabled.
Stop Bits
The number of Stop bits per character. The number of Stop bits is always 1.
Parity Type
The Parity Method used on the Serial Port. The Parity Method is always None.
Default
enabled
Format
ip telnet server enable
Mode
Privileged EXEC
Format
no ip telnet server enable
Mode
Privileged EXEC
Содержание CP6923
Страница 4: ...Page iv ...
Страница 35: ...Using the Command Line Interface Chapter 1 1 Page 1 1 CP6923 CLI Reference Manual CP6923 ...
Страница 44: ...Using the Command Line Interface CP6923 CP6923 CLI Reference Manual Page 1 10 ...
Страница 45: ...Switching Commands Chapter 1 2 Page 2 1 CP6923 CLI Reference Manual CP6923 ...
Страница 174: ...Switching Commands CP6923 CP6923 CLI Reference Manual Page 2 130 ...
Страница 175: ...Quality of Service Commands Chapter 1 3 Page 3 1 CP6923 CLI Reference Manual CP6923 ...
Страница 213: ...Routing Commands Chapter 1 4 Page 4 1 CP6923 CLI Reference Manual CP6923 ...
Страница 285: ...Multicast Commands Chapter 1 5 Page 5 1 CP6923 CLI Reference Manual CP6923 ...
Страница 314: ...Multicast Commands CP6923 CP6923 CLI Reference Manual Page 5 30 ...
Страница 315: ...Utility Commands Chapter 6 Page 6 1 CP6923 CLI Reference Manual CP6923 ...
Страница 387: ...Management Commands Chapter 1 7 Page 7 1 CP6923 CLI Reference Manual CP6923 ...
Страница 428: ...Management Commands CP6923 CP6923 CLI Reference Manual Page 7 42 ...
Страница 429: ...CP6923 Page A 1 CP6923 CLI Reference Manual Getting Help Appendix A ...
Страница 434: ...CP6923 Page B 1 CP6923 CLI Reference Manual FASTPATH log messages Appendix B ...
Страница 450: ...CP6923 Page C 1 CP6923 CLI Reference Manual List of Commands Appendix C ...