Technical data
Proline Promag W 500 PROFINET
222
Hauser
Nominal diameter
Recommended
flow
Factory settings
min./max. full
scale value
(v ~ 0.3/10 m/s)
Full scale value
current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[mm]
[in]
[dm
3
/min]
[dm
3
/min]
[dm
3
]
[dm
3
/min]
80
3
90 to 3
000
750
5
12
100
4
145 to 4
700
1200
10
20
125
–
220 to 7
500
1850
15
30
Flow characteristic values in SI units: DN 150 to 2400 (6 to 90")
Nominal diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s)
Full scale
value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut
off
(v ~
0.04 m/s)
[mm]
[in]
[m
3
/h]
[m
3
/h]
[m
3
]
[m
3
/h]
150
6
20 to 600
150
0.025
2.5
200
8
35 to 1
100
300
0.05
5
250
10
55 to 1
700
500
0.05
7.5
300
12
80 to 2
400
750
0.1
10
350
14
110 to 3
300
1000
0.1
15
375
15
140 to 4
200
1200
0.15
20
400
16
140 to 4
200
1200
0.15
20
450
18
180 to 5
400
1500
0.25
25
500
20
220 to 6
600
2000
0.25
30
600
24
310 to 9
600
2500
0.3
40
700
28
420 to 13
500
3500
0.5
50
750
30
480 to 15
000
4000
0.5
60
800
32
550 to 18
000
4500
0.75
75
900
36
690 to 22
500
6000
0.75
100
1000
40
850 to 28
000
7000
1
125
–
42
950 to 30
000
8000
1
125
1200
48
1
250 to 40
000
10000
1.5
150
–
54
1
550 to 50
000
13000
1.5
200
1400
–
1
700 to 55
000
14000
2
225
–
60
1
950 to 60
000
16000
2
250
1600
–
2
200 to 70
000
18000
2.5
300
–
66
2
500 to 80
000
20500
2.5
325
1800
72
2
800 to 90
000
23000
3
350
–
78
3
300 to 100
000
28500
3.5
450
2000
–
3
400 to 110
000
28500
3.5
450
–
84
3
700 to 125
000
31000
4.5
500
2200
–
4
100 to 136
000
34000
4.5
540
Содержание Proline Promag W 500