Proline Promag W 500 PROFINET
Technical data
Hauser
223
Nominal diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s)
Full scale
value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut
off
(v ~
0.04 m/s)
[mm]
[in]
[m
3
/h]
[m
3
/h]
[m
3
]
[m
3
/h]
–
90
4
300 to 143
000
36000
5
570
2400
–
4
800 to 162
000
40000
5.5
650
Flow characteristic values in SI units: DN 50 to 300 (2 to 12") for order code for "Design",
option C "Fixed flange, without inlet/outlet runs"
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.12/5 m/s)
Full scale value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 4 pulse/s)
Low flow cut off
(v ~ 0.01 m/s)
[mm]
[in]
[m
3
/h]
[m
3
/h]
[m
3
]
[m
3
/h]
50
2
15 to 600 dm
3
/min
300 dm
3
/min
1.25 dm
3
1.25 dm
3
/min
65
–
25 to 1
000 dm
3
/min
500 dm
3
/min
2 dm
3
2 dm
3
/min
80
3
35 to 1
500 dm
3
/min
750 dm
3
/min
3 dm
3
3.25 dm
3
/min
100
4
60 to 2
400 dm
3
/min
1
200 dm
3
/min
5 dm
3
4.75 dm
3
/min
125
–
90 to 3
700 dm
3
/min
1
850 dm
3
/min
8 dm
3
7.5 dm
3
/min
150
6
145 to 5
400 dm
3
/min
2
500 dm
3
/min
10 dm
3
11 dm
3
/min
200
8
220 to 9
400 dm
3
/min
5
000 dm
3
/min
20 dm
3
19 dm
3
/min
250
10
20 to 850
500
0.03
1.75
300
12
35 to 1
300
750
0.05
2.75
Flow characteristic values in US units: 1 to 48" (DN 25 to 1200)
Nominal diameter
Recommended
flow
Factory settings
min./max. full
scale value
(v ~ 0.3/10 m/s)
Full scale value
current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[in]
[mm]
[gal/min]
[gal/min]
[gal]
[gal/min]
1
25
2.5 to 80
18
0.2
0.25
–
32
4 to 130
30
0.2
0.5
1 ½
40
7 to 185
50
0.5
0.75
2
50
10 to 300
75
0.5
1.25
–
65
16 to 500
130
1
2
3
80
24 to 800
200
2
2.5
4
100
40 to 1
250
300
2
4
–
125
60 to 1
950
450
5
7
6
150
90 to 2
650
600
5
12
8
200
155 to 4
850
1200
10
15
10
250
250 to 7
500
1500
15
30
12
300
350 to 10
600
2400
25
45
Содержание Proline Promag W 500