Operation
Proline Promag W 500 PROFINET
160
Hauser
11.4.1 "Process variables" submenu
The
Process variables
submenu contains all the parameters needed to display the current
measured values for each process variable.
Navigation
"Diagnostics" menu → Measured values → Process variables
‣
Process variables
Volume flow
Mass flow
Corrected volume flow
Flow velocity
Conductivity
Density
Parameter overview with brief description
Parameter
Description
User interface
Volume flow
Displays the volume flow that is currently measured.
Dependency
The unit is taken from the
Volume flow unit
parameter
Signed floating-point number
Mass flow
Displays the mass flow currently calculated.
Dependency
The unit is taken from the
Mass flow unit
parameter
Signed floating-point number
Corrected volume flow
Displays the corrected volume flow that is currently calculated.
Dependency
The unit is taken from the
Corrected volume flow unit
Signed floating-point number
Flow velocity
Displays the flow velocity that is currently calculated.
Signed floating-point number
Conductivity
Displays the conductivity that is currently measured.
Dependency
The unit is taken from the
Conductivity unit
parameter
Signed floating-point number
Density
Displays the current fixed density or density read in from an
external device.
Dependency
The unit is taken from the
Density unit
parameter.
Signed floating-point number
11.4.2 Totalizer
The
Totalizer
submenu contains all the parameters needed to display the current
measured values for every totalizer.