Proline Promag W 500 PROFINET
Electrical connection
Hauser
71
Current input
3
1
4
2
A0028915
29
Connection example for 4 to 20 mA current input
1
Power supply
2
Terminal box
3
External measuring device (for reading in pressure or temperature, for instance)
4
Transmitter
Status input
1
2
3
A0028764
30
Connection example for status input
1
Automation system with status output (e.g. PLC)
2
Power supply
3
Transmitter
7.6
Hardware settings
7.6.1
Setting the device name
A measuring point can be quickly identified within a plant on the basis of the tag name.
The tag name is equivalent to the device name (name of station of the PROFINET
specification). The factory-assigned device name can be changed using the DIP switches or
the automation system.
Example of device name (factory setting): EH-Promag500-XXXX
EH
Hauser
Promag
Instrument family
500
Transmitter
XXXX
Serial number of the device
The device name currently used is displayed in Setup → Name of station is also displayed.