Proline Promag W 500 PROFINET
Technical data
Hauser
227
16.4 Output
Output signal
PROFINET
Standards
In accordance with IEEE 802.3
Current output 0/4 to 20 mA
Current output
0/4 to 20 mA
Current range
Can be set to:
• 4 to 20 mA (passive)
• 0/4 to 20 mA (active)
Maximum output values
22.5 mA
Open-circuit voltage
DC 28.8 V (active)
Maximum input voltage
DC 30 V (passive)
Load
0 to 700 Ω
Resolution
0.38 µA
Damping
Configurable: 0.07 to 999 s
Assignable measured
variables
• Volume flow
• Mass flow
• Corrected volume flow
• Flow velocity
• Conductivity
• Electronics temperature
Current output 0/4 to 20 mA Ex i
Current output
0/4 to 20 mA Ex i
Current range
Can be set to:
• 0/4 to 20 mA (active)
• 4 to 20 mA (passive)
Maximum output values
22.5 mA
Open-circuit voltage
DC 21.8 V (active)
Maximum input voltage
DC 30 V (passive)
Load
• 0 to 400 Ω (active)
• 0 to 700 Ω (passive)
Resolution
0.38 µA
Damping
Configurable: 0.07 to 999 s
Assignable measured
variables
• Volume flow
• Mass flow
• Corrected volume flow
• Flow velocity
• Conductivity
• Electronics temperature