Technical data
Proline Promag W 500 PROFINET
236
Hauser
Sensor
• As standard: IP66/67, type 4X enclosure
• Optionally available for order:
• IP66/67, type 4X enclosure; fully welded, with protective varnish EN ISO 12944 C5-M.
Suitable for use in corrosive atmospheres.
• IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944 C5-
M. Suitable for permanent immersion in water ≤ 3 m (10 ft) or up to 48 hours at
depths ≤ 10 m (30 ft).
• IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944
Im1/Im2/Im3. Suitable for permanent immersion in saline water ≤ 3 m (10 ft) or up to
48 hours at depths ≤ 10 m (30 ft) or in buried applications.
External WLAN antenna
IP67
Vibration resistance
• Vibration, sinusoidal according to IEC 60068-2-6
• 2 to 8.4 Hz, 7.5 mm peak
• 8.4 to 2
000 Hz, 2 g peak
• Vibration broad-band random, according to IEC 60068-2-64
• 10 to 200 Hz, 0.01 g
2
/Hz
• 200 to 2
000 Hz, 0.003 g
2
/Hz
• Total: 2.70 g rms
Shock resistance
Shock, half-sine according to IEC 60068-2-27
6 ms 50 g
Shock resistance
Shock due to rough handling following IEC 60068-2-31
Mechanical load
• Protect the transmitter housing against mechanical effects, such as shock or impact; the
use of the remote version is sometimes preferable.
• Never use the transmitter housing as a ladder or climbing aid.
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.
16.9 Process
Medium temperature range
• 0 to +80 °C (+32 to +176 °F) for hard rubber, DN 50 to 2400 (2 to 90")
• –20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 1200 (1 to 48")
• –20 to +90 °C (–4 to +194 °F) for PTFE, DN 25 to 300 (1 to 12")