background image

English

A&D MX-50 / MF-50  Instruction Manual

Содержание MX-50

Страница 1: ...E n g l i s h A D MX 50 MF 50 Instruction Manual...

Страница 2: ...lection of Measurement Method 15 7 1 Measurement Condition 15 7 2 Operation in User Mode 16 8 Connecting to a Printer 18 9 Connecting to a Computer 20 9 1 RS 232C Serial Interface 20 9 2 Output Format...

Страница 3: ...ogen lamp are connected to high voltage Do not disassemble the analyser It may result in malfunction causing an electric shock or fire If the analyser needs service or repair contact the local A D dea...

Страница 4: ...adiate radio frequency energy This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules These rules are de...

Страница 5: ...ying process Spread the sample on sample pan as evenly as possible Apply an optimal sample weight If the sample weight is too small precise results may not be possible To repeat measurements keep the...

Страница 6: ...iffers by model Maximum number MX 50 results of 100 MF 50 results of 50 The software WinCT Moisture an accessory of the MX 50 has 3 separate software programs RS Key can allow data from the moisture b...

Страница 7: ...r t 4 Handle of heater cover Bubble level Keys Reference card Display Power supply label on the back panel Heater cover Handle of heater cover Power switch Sample pan handle Leveling foot Sample pan...

Страница 8: ...plug type and power cord Sample pan 20 pieces Pan support Pan handle 2 pieces Breeze break ring Dust cover Instruction manual Fuse T100mA 250V Fuse T6 3A 250V Display cover Power cord RS 232C serial...

Страница 9: ...ht or Drying rate 6 Unit 7 Value 8 Temperature of sample pan 9 Time Standard Mode State Meaning Gram display Program Number Storing data Number of results in Memory Indicates accuracy of measurement I...

Страница 10: ...e guide holes of the Breeze Break to the guides on the body 5 Hook the pan handle into the cut out of the rim of the breeze break ring 6 Place the pan support Align signs of the pan support and the bo...

Страница 11: ...ds to step 5 Symbols and arrangement of the calendar y d Year month day dy Month day year d y Day month year The arrangement of the calendar is used for the report of GLP GMP and ISO 5 Time is display...

Страница 12: ...s displayed Example CH no error 0 or Ht err 0 000 0 000 PROGRAM CH CH ENTER CH pa55 6 1 Standard Mode The Standard Mode provides measurements of moisture content simply by selecting desirable accuracy...

Страница 13: ...the SELECT key to select the drying temperature 6 Press the or key to select the temperature To store the parameters and finish the operation proceed to step11 Select a Unit Refer the Unit Chart at 7...

Страница 14: ...ess the START key after the weight value has become stable Finish the Measurement 18 When the Drying Rate reaches to the preset value the measurement is completed and the buzzer beeps ENTER key Result...

Страница 15: ...omplete condition unit and decimal point Maximum number MX 50 20 sets Program number PROG 1 to 20 MF 50 10 sets Program number PROG 1 to 10 This function is operated by the program number PROG and can...

Страница 16: ...C Set the Analysing mode 7 Press the SELECT key to select the analysing mode and press the or key to set 0 02 min To store the parameters and finish the operation proceed to step 12 Timer mode sets th...

Страница 17: ...ero press the RESET key 16 Open the heater cover Remove the sample pan using the sample pan handle and replace when sample has been added Caution The sample needs to be more than 0 1 g Spread the samp...

Страница 18: ...the result and change of Drying Rate can be printed using the statistical function of the AD 8121 Use the standard AD 8121 accessory cable Printer Setting List Purpose Analyser settings AD 8121 settin...

Страница 19: ...g Practice ISO International Organisation for Standardisation Use the standard DP 1012 balance cable Printer Setting List Purpose Analyser settings DP 1012 settings Prt 5 d info Data for GLP GMP and I...

Страница 20: ...s the accessory software WinCT for windows It can transmit data to a PC that is working on Microsoft Windows to monitor data and to check the measurement condition 9 1 RS 232C Serial Interface RS 232C...

Страница 21: ...ot connect Other Not used 9 2 Output Format Format without Temperature Data Function Table 5 d 0 The format consists of fifteen characters except the terminator A polarity sign is placed before the da...

Страница 22: ...excluding the terminator 9 3 Command The analyser can be controlled by the following commands from the computer Add a terminator 0Dh 0Ah to each command Command Description Q Outputs the current data...

Страница 23: ...pressed during a measurement except in manual mode the result will not be stored 10 1 1 Function Setting This example selects store result from the Function Table Refer to Section 12 1 Turn on the an...

Страница 24: ...nd is displayed 7 Press the RESET key to return to the weighing mode 10 1 3 Delete All Data at One Time 1 Turn on the analyser The display will show 0 000 g 2 Press and hold the ENTER key to display o...

Страница 25: ...store an ID number to be used in the calibration report The number can also be used for management and maintenance of the analyser 11 1 Setting Identification Number ID No The ID number consists of t...

Страница 26: ...key to display CAL 5 Press the ENTER key to display CAL 0 6 If 20g weight is used Press the ENTER key Proceed to step8 If 50g weight is used Press the SELECT key Proceed to step7 7 Press the or key t...

Страница 27: ...60 C Each adjustment needs fifteen minutes The buzzer sounds at the end t Up is displayed after no adjustment for five minutes during the operation and calibration is stopped Press any key to return t...

Страница 28: ...e 97 C 9 Press the ENTER key to store the new data and to proceed to the 160 C measurement 10 After fifteen minutes the buzzer sounds and the display blinks 160 C Adjust the value to be the same as th...

Страница 29: ...inter use printer MODE 3 CALIBRATED TEMPERATURE TARGET ACTUAL 100 C 97 C 160 C 162 C SIGNATURE A D MODEL S N ID DATE TIME MX 50K K1234567 LAB 123 2002 04 15 12 34 56 Manufacture Model Serial number ID...

Страница 30: ...Fo 1 GLP GMP ISO data formatting for calibration data output GMP and ISO ID number id ID number setting Factory settings CLr Resets the analyser to the factory settings 1 Factory settings 2 Use this p...

Страница 31: ...able 2 Press the SELECT key to display dP 3 Press the ENTER key to enter the item 4 Press the or key to display dP 1 5 Press the ENTER key to store new parameter 6 Press the RESET key to return to the...

Страница 32: ...ctive Use the halogen lamp accessory AX MX 34 240V The life time of the halogen lamp is approximately 5000 hours 13 1 1 Replacement of the Halogen Lamp Caution Clean the surface of the halogen lamp If...

Страница 33: ...nalyser The display will show 0 000 g 2 Press and hold the SELECT key to enter the function table 3 Press the SELECT key several times to display CLr 4 Press the ENTER key to enter the item 5 Press th...

Страница 34: ...Check that the rated voltage of the halogen lamp is correct Read the power supply voltage label on the back of the heater cover and confirm that the rated voltage of the halogen lamp is correct for y...

Страница 35: ...e Control Error If this error is not cleared by turning the power switch off for more than a half hour contact the local A D dealer to repair the analyser Time Error at Temperature Calibration If no k...

Страница 36: ...the preset drying time measurement is automatically stopped 1min to 480 min Manual mode When pressing the key at any time measurement is stopped and the result is decided Measurement unit Moisture con...

Страница 37: ...AX MX 39 RS 232C cable 2m 25 pins 9 pins AX MX 40 Calibration mass 20g equivalent to OIML class F1 WTF1 20G WinCT Moisture CD ROM Application software for Windows AX MX 42 Certified temperature calib...

Страница 38: ...ment 5 CR 20 CTS 21 data 30 Data bits 20 Data memory 23 Data memory function 23 30 Data output mode 30 STOP START SELECT RESET PROGRAM ENTER Decimal point 13 30 Display 7 9 dmy 11 Dot 30 DOWN command...

Страница 39: ...ET command 22 RESET key 9 RS 232C serial interface 7 20 RTS 21 RXD 21 Safty 3 Sample 14 Sample mass 15 Sample pan 7 8 SELECT command 22 SELECT key 9 SG 21 SIR command 22 Sodium tartrate dihydrate 6 So...

Отзывы: