Command Reference A-71
NAME
ping - send ICMP ECHO_REQUEST packets to network hosts
SYNOPSIS
ping
[ -
s
] [ -
Rrv
]
host
[
packetsize
[
count
] ]
DESCRIPTION
ping
uses the ICMP protocols mandatory ECHO_REQUEST datagram to elicit an
ICMP ECHO_RESPONSE from the specified
host
or gateway. ECHO_REQUEST
datagrams have an IP and ICMP header, followed by a
struct
timeval
and then an
arbitrary number of bytes used to fill out the packet. If
host
responds,
ping
prints
host
is alive. Otherwise,
ping
will resend the ECHO_REQUEST once a sec-
ond. If the
host
does not respond after
count
seconds (default value is 20),
ping
will print no answer from
host
.
When the -
s
flag is specified,
ping
sends one datagram per second and prints
one line of output for every ECHO_RESPONSE that it receives.
ping
computes
the round-trip times and packet loss statistics. When the
count
number of pack-
ets have been sent or if the command is terminated with a ^C, the summary
statistics is displayed. The default
packetsize
is 56, which translates into 64 ICMP
bytes when combined with the 8 bytes of ICMP header.
OPTIONS
-
R
Record route. Includes the RECORD_ROUTE option in the ECHO_REQUEST
packet and displays the route buffer on returned packets. Note that the IP
header is only large enough for nine such routes. Many hosts ignore or dis-
card this option.
-
r
Bypass the normal routing tables and send directly to a host on an attached
network. If the host is not on a directly-attached network, an error is
returned.
-
s
Send one datagram every second.
-
v
Verbose output. ICMP packets other than ECHO_RESPONSE that are
received are listed.
SEE ALSO
ifconfig, netstat
ping
Содержание PowerVault 720N
Страница 1: ... ZZZ GHOO FRP HOO 3RZHU9DXOW 1 1 DQG 1 6 67 0 0 1 675 725 1 200 1 5 5 1 8 ...
Страница 6: ...viii ...
Страница 48: ...l ...
Страница 124: ...3 28 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 252: ...8 12 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 280: ...10 10 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 332: ...14 6 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 344: ...15 12 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 362: ...16 18 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 372: ...17 10 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 392: ...18 20 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 414: ...19 22 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 416: ...A 2 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 417: ...Command Reference A 3 8VHU RPPDQGV This section contains user commands ...
Страница 438: ...A 24 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide SEE ALSO maxfiles rc snap df ...
Страница 503: ...Command Reference A 89 SEE ALSO ifconfig reboot dgateways exports hosts hosts equiv resolv conf rc autosupport setup ...
Страница 531: ...Command ReferenceA 117 ...
Страница 573: ...Command Reference A 159 6 VWHP 6HUYLFHV DQG DHPRQV This section contains system services and daemons ...
Страница 588: ...A 174 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...