File Sharing Between NFS and CIFS Users5-19
The
-v
option increases the level of detail of information. The kind of information var-
ies with each command. You can have up to three instances of the -v option (-vvv) per
command. Each repetition of the option increases the level of detail; three instances
provide statistics that are only of interest to Dell technical support.
RZ/RQJ(DFK:$)/&UHGHQWLDO
&DFKH(QWU\,V9DOLG
'HVFULSWLRQ
This procedure enables you to change how long each WAFL credential cache entry is
valid. If you need to see security updates as they occur, you might want to use a
smaller value than the default. However, access verifications are more frequent than
with a greater value. This means that with a smaller value, users might experience
slower performance.
wcc -x
[-f] [-v]
Removes all entries from the WAFL cre-
dential cache.
The
-v
option displays how many entries
have been removed.
-i
ip-addr
[-v]
Removes all entries from the WAFL cre-
dential cache with the same IP address.
The
-v
option displays how many entries
have been removed.
-s
ntname
[-i
ip-addr
]
[-v]
Removes the entries with the given Win-
dows NT name and optional qualifying IP
address. If the Windows NT name is the
name of a group, removes all members of
that group from the WAFL credential
cache.
The
-v
option displays how many entries
have been removed.
-u
uname
[-i
ip-addr
]
[-v]
Removes the entries with the given UNIX
name and optional qualifying IP address.
The
-v
option displays how many entries
have been removed.
7DEOHZFF&RPPDQG2SWLRQV
FRQWLQXHG
7\SH
2WKHURSWLRQV
)XQFWLRQ
Содержание PowerVault 720N
Страница 1: ... ZZZ GHOO FRP HOO 3RZHU9DXOW 1 1 DQG 1 6 67 0 0 1 675 725 1 200 1 5 5 1 8 ...
Страница 6: ...viii ...
Страница 48: ...l ...
Страница 124: ...3 28 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 252: ...8 12 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 280: ...10 10 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 332: ...14 6 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 344: ...15 12 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 362: ...16 18 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 372: ...17 10 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 392: ...18 20 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 414: ...19 22 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 416: ...A 2 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...
Страница 417: ...Command Reference A 3 8VHU RPPDQGV This section contains user commands ...
Страница 438: ...A 24 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide SEE ALSO maxfiles rc snap df ...
Страница 503: ...Command Reference A 89 SEE ALSO ifconfig reboot dgateways exports hosts hosts equiv resolv conf rc autosupport setup ...
Страница 531: ...Command ReferenceA 117 ...
Страница 573: ...Command Reference A 159 6 VWHP 6HUYLFHV DQG DHPRQV This section contains system services and daemons ...
Страница 588: ...A 174 Dell PowerVault 720N 740N and 760N System Administrator and Command Reference Guide ...