5.9 Electrical System
05-193
5.9.2.6 Starter Relay
●Load 12V between positive and negative
terminal. Use multimeter to check if there
is continuity between 2 contacts.
●If multimeter clicks, there is continuity
between contacts.
●If 12V is removed, no continuity remains
between contacts.
●If both the above two items are in good
condition, it indicates the replay is well.
Turn multimeter to DIODE.
0519301
Note: Loading voltage between
terminals can not exceed 2 minutes,
otherwise, starter relay may overheat or
burn.
●Use multimeter to measure starter relay
coil resistance, if the reading is out of
specification, replace a new relay.
●Turn multimeter to 1×10Ω
Starter Relay Coil Resistance: 3Ω~5Ω
0519302