8-23
IM 701210-05E
Display
8
8.13 Displaying Channel Information/Displaying Waveforms on a Full Screen (Expanding the Waveform Area)
Note
•
Each time you press the ESC key, the display switches cyclically as follows: channel
information display
→
numeric monitor display
→
full screen display of waveforms full
→
channel information display.
•
When the DL750/DL750P receives communication commands, the screen switches to
channel information display.
Explanation
Displaying the Channel Information
Pressing the ESC key once when the setup menu is displayed shows the channel
information. The parameters displayed in the channel information are as follows.
However, not all parameters may be displayed when the number of display channels
increases.
• When measuring voltage:
V/div setting, input coupling, probe attenuation
(type), and bandwidth limit.
• When measuring temperature:
Temperature/div setting, thermocouple type, and
bandwidth limit.
• When measuring strain:
µ
STR/div (or [mV/V]/div) setting, measurement
range, and bandwidth limit.
• When measuring acceleration*:
Acceleration/div setting, gain, input coupling, and
bias setting.
• When measuring the frequency*: Value/div setting, measurement mode setting, and
preset setting.
• For DSP channels:
Value/div setting and computing equation.
*
Some items may not be displayed depending on the amount of information present.
Displaying the Numeric Monitor
Pressing ESC key once when the channel information is displayed clears the channel
information and shows the numeric monitor of the channels (CH1 to CH16, LogicA,
LogicB, DSP1 to DSP6 (option)) whose display is turned ON is displayed.
The display update interval of numeric monitor is 1 s.
Note
Notation of the Numeric Monitor of Logic Waveforms
The numeric monitor of logic waveforms (Logic A or Logic B) is displayed in binary or
hexadecimal notation.
Select the notation by carrying out the following procedure.
Press the CURSOR key > Type soft key > Vertical soft key, press the Logic Setup soft key
that appears when Trace is set to All, LogicA, LogicB, or LogicA & LogicB, and set Format to
Binary or Hexa. For details, see step 1 to 7 on page 11-18 and “Display Format of Logic
Waveforms” on page 11-28.
• Binary
• Hexadecimal
Expanding the Waveform Display Area
Pressing the ESC key once when the channel information is displayed clears the channel
information and expands the waveform display area horizontally to cover the entire screen.
The waveform display area is expanded at power up.
Displaying the Parameter That Was Controlled by the Jog Shuttle Immediately
Before Pressing the ESC Key
The parameter that was controlled by the jog shuttle immediately before can be
displayed by pressing the SELECT key when the channel information is displayed or
when the waveform display area is expanded. The setting of this parameter can be
changed by operating the jog shuttle in the usual manner. To clear the display of the
parameter, press the ESC key.