3-15
INSP
ADJ
E
JET PUMP UNIT/GENERAL
Water inlet strainer inspection
1. Inspect:
●
Water inlet strainer
Contaminants
→
Clean.
Cracks/damage
→
Replace.
Inspection steps:
●
Remove the ride plate.
Refer to “JET PUMP UNIT” in Chapter
6.
●
Remove the water inlet cover
1
.
●
Inspect the water inlet strainer mesh
a
.
●
Install the water inlet cover.
●
Install the ride plate.
Refer to “JET PUMP UNIT” in Chapter
6.
Bilge strainer inspection
1. Inspect:
●
Bilge strainer
Contaminants
→
Clean.
Cracks/damage
→
Replace.
Inspection steps:
●
Remove the ventilation hose and elec-
trical box.
Refer to “ELECTRICAL BOX” in Chap-
ter 7.
●
Remove the coupling cover.
●
Disconnect the bilge strainer
1
from
the bilge strainer holder.
●
Inspect the bilge strainer.
●
Install the coupling cover.
●
Install the electrical box and ventila-
tion hose.
Refer to “ELECTRICAL BOX” in Chap-
ter 7.
GENERAL
Drain plug inspection
1. Inspect:
●
Drain plugs
Cracks/damage
→
Replace.
●
O-rings
Cracks/wear
→
Replace.
●
Screw threads
Contaminants
→
Clean.