Tolerances
JAM Protection: JAM [x]
Tolerance
Pickup
±1.5% of the setting value resp. 1% In
Resetting ratio
97% or 0.5% x In
t
DEFT
±1% resp. ±10 ms
Operating time
<65 ms
Release time
<45 ms
Undercurrent Protection: I< [x]
Tolerance
I<
±1.5% of the setting value resp. 1% In
Resetting ratio
97% or 0.5% x In
t
DEFT
±1% resp. ±10 ms
Operating time
<65 ms
Release time
<45 ms
Mechanical Load Shedding MLS
Tolerance
Pickup Threshold
±1.5% of the setting value resp. 1% In
Resetting ratio
97% or 0.5% x In
t-Pickup Delay
DEFT
±1% resp. ±10 ms
Dropout Threshold
±1.5% of the setting value resp. 1% In
Resetting ratio
97% or 0.5% x In
t-Drop Delay
DEFT
±1% resp. ±10 ms
Operating time
<65 ms
Release time
<45 ms
Circuit Breaker Failure Protection CBF
Tolerance
I-CBF>
±1.5% of the setting value resp.1% In
resetting ratio
0.5% x In
t-CBF
±1% resp. ±10 ms
Operating time
Starting from I higher than 1.3 x I-CBF>
<40 ms
Release time
<40 ms