Communication Protocols
Direct Commands of the IRIG-B00X
Parameter
Description
Setting range
Default
Menu path
Res IRIG-B Cr
Resetting of the
Diagnosis Counters:
IRIG-B.
inactive,
active
inactive
[Operation
/Reset
/Counter]
Global Protection Parameters of the IRIG-B00X
Parameter
Description
Setting range
Default
Menu path
Function
Permanent activation or
deactivation of
module/stage.
inactive,
active
inactive
[Device Para
/IRIG-B]
IRIG-B00X
Determination of the
Type: IRIG-B00X. IRIG-B
types differ in types of
included “Coded
Expressions” (year,
control-functions,
straight-binary-seconds).
IRIB-000,
IRIB-001,
IRIB-002,
IRIB-003,
IRIB-004,
IRIB-005,
IRIB-006,
IRIB-007
IRIB-000
[Device Para
/IRIG-B]
Page 210
EN MRM4 01/11
Summary of Contents for MRM4
Page 1: ...MRM4 HighPROTEC Motor Protection Device Manual DOK HB MRM4E...
Page 3: ...Order Code EN MRM4 01 11 Page 3...
Page 18: ...Important Definitions Page 18 EN MRM4 01 11 41 SG Prot ON 42 SG ON Cmd SG Prot ON SG ON Cmd...
Page 115: ...Navigation Operation Navigation Operation EN MRM4 01 11 Page 115 1 2 3 5 7 6 8 10 9...
Page 162: ...Recorder Name Description I 2 TripCmd Signal Trip Command Page 162 EN MRM4 01 11...